November 22, 2008    Support  Contact  
*Important Notice:
This site requires Adobe Flash 8 or better.
You need to upgrade your Flash Player.
Get flash player
  Search:      Advanced search
  Home       Shopping Cart       Checkout       Help    
 
 Categories

 Manufacturers
Akumen RAIDS
Addlogix
Arena Maxtronic
ATTO Technology
CalDigit
DATOptic
Enhance Tech RAID
G-Technology
ICYDOCK
HighPoint Technologies
NitroAV
Sonnet Tech
Xterasys
** ServiceDept **

 Currency Selector
US Dollar Canadian Dollar EURO
British Pounds Peso

 Bestsellers
1. Arena Maxtronic 8-Bay U320 SA-3340 JanusRAID -SATA II Tower RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300W x 2 Redundant Hot Swap P/S, Hot Swap HDD Trays
2. Arena Maxtronic 12 Bay 2U SA-4540S JanusRAID SATA II- U320SCSI Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 460WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays
3. Arena Maxtronic 8-Bay U320 SA-4340S JanusRAID -S-ATA Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300W x 2 Redundant Hot Swap P/S, Hot Swap HDD Trays
4. Arena Maxtronic 16-Bay 3U JanusRAID SA-6643S SATA-II - iSCSI Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays
5. Arena Maxtronic 250W Redundant Power Supply - Part No. D002702 for ID-2231 and AE-5630 RAIDS

 Special
Gift certificates
Price Lists

 Help
About Akumen Online
Contact us
Help Desk Support
How To Order
Live Chat Support
Payment Methods
Policies & Procedures
Privacy Statement
Return Policy
Shipping Methods

  Verge Labs Inc. (Akumen.com) :: Arena Maxtronic :: Arena Maxtronic 16-Bay 3U JanusRAID SA-6643S SATA-II - iSCSI Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays

  Arena Maxtronic 16-Bay 3U JanusRAID SA-6643S SATA-II - iSCSI Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays #620

Arena Maxtronic 16-Bay 3U JanusRAID SA-6643S SATA-II - iSCSI Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays



  ::  DETAILS
  • SKU: SA-6643S-AM
  • Price: $4,588.95

  • Options:
  • HDD Configured Systems:
  • Quantity :


  •         
 

  ::  OVERVIEW
The JanusRAID SA-6643S is a single controller, iSCSI to SATA-II RAID system. In a compact 3U - 16 bay chassis, featuring hot-swappable power supplies and fans. The RAID controller, fans, and power supplies are modularized allowing for easy removal from the rear of the unit. System setup is simple using a java-based web browser allowing easy remote configuration and monitoring. Copy-on-Write snapshot functionality is built into the controller to help protect your data.

iSCSI protocol uses TCP/IP to transfer data, which only requires an ethernet interface, and enables easy integration into your current network infrastructure. iSCSI encapsulates SCSI commands and data into TCP/IP packets to transfer through a ethernet network. By using TCP/IP to transfer ensures that the transmission is successful, and provides a reliable means of transfering data. Also, by using your current network infrastructure reduces the total cost of ownership.

  ::  KEY FEATURES
    - Snapshot and Rollback
    The SA-6643S implements a is Copy-on-Write snapshot technology implemented that utilizes a small pre-designated volume for the snapshot, known as the snapshot UDV. When the snapshot is initially setup, metadata, or a table of contents, of the original volume is copied, and thus makes the snapshot instantaneous. Before new data is written the original data is copied to the snapshot UDV, and the new data is written to the original data blocks. In the event of file corruption, accidental overwriting, or a virus infection, a rollback can be performed to restore any remaining original data.

    - Online Volume Group, User Data Volume Expansion and RAID Level Migration
    Volume Groups can be easily expanded using built-in GUI utilities, allowing your storage requirements to grow when your needs grow. Likewise, User Data Volumes (UDV) can be expanded online. A unique feature to the SA-6643S is RAID level migration, which allows you to upgrade, or downgrade, RAID levels online.

    - RAID 6
    RAID 6 improves over the industry standard RAID 5 by adding another parity disk which enables greater reliability and data protection.

    - SCSI Enclosure Services (SES) management
    This feature allows users to communicate using an iSCSI initiator to the RAID subsystem to monitor voltages, temperature, and other diagnostic information.

    - MPIO and MC/S Ready
    Multipath I/O and Multiple Connection per session use physical paths to create logical paths between the host and storage device. If a physical path were to fail, the multipath software will use an alternate path to the storage device to enable users continued access to their data.

    - CHAP Authentication
    Challenge Handshake Authorization Protocol, or CHAP, is a powerful authentication method used for point-to-point user login. When using CHAP, the server will send an authentication key to the client for encrypting the username and password. By using the CHAP authentication, the user login process will be encrypted and secure.

    - Link Aggregation or Trunking
    Link Aggregation Control Protocol (LACP), part of IEEE 802.32ad, allows users to bind together both Ethernet ports of the SA-6643S into a single logical channel to increase bandwidth. Trunking uses similar binding methods, combining both Ethernet ports as a single logical port, can increase the bandwidth as well.

    - Global or Dedicated cache by volume
    Controller cache can be configured as Global or Dedicated for specific volumes. This function provides users the ability to dedicate more cache resources to a mission-critical volume to enable higher performance and reliability.

    - BBU
    An optional BBU can be included in the RAID system to ensure data integrity in the event of a power outage. The BBU, or battery backup unit, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.

  ::  TECHNICAL SPECIFICATIONS
    Host Interface: iSCSI
    Data Transfer Rate: Up to 300 MB per second
    Number of Host Channels: 2
    External Connector Type: 3 x RJ-45 ( 1 console port, 2 data port)

    Controller CPU: Intel i80331 RISC CPU
    Cache Memory: 512MB - Upgradeable to 1GB DDR 333 SDRAM (PC2700 184-pin DIMM)
    Disk Interface: SATA-II (3 Gb/sec)
    Number of Disk Channels: 16
    Hot Swap Disk Tray: 16 x 3.5" hot-swappable trays
    Hot Swap Fan: 2x 3600RPM Turbo Fan
    Hot Swap Power supplies: 460watt x 2 Redundant
    AC Input Voltage: 100 to 240V (+/- 10%), 46 to 63 Hz

    RAID Levels: JBOD, 0, 1, 0+1, 3, 5, 6, 10, 30, 50, 60
    RAID Arrays: 16 Maximum
    Data Rebuild: Automatic Data Regeneration
    RAID Features: Global or Dedicated Hotspare, Multiple Host ID, Multiple RAID Volume Group, Multiple User Data Volumes, and Foreground or Background Initialization, Array Roaming
    Remote Backup: Optional
    Snapshot: Yes (Copy-on-Write)

    Front Panel LCD and Buttons: Easy access for configuration and status report.
    RS-232 Terminal: User Friendly interface for configuration and status report
    Web browser GUI: Embedded GUI management interface
    Event Notification: Built-in buzzer, e-mail, and SNMP

    Humidity: 10% to 85% non-condensing
    Operating Temp: 5 C to 40 C
    Non-Operating Temp: -25 C to 60 C
    Safety Regulatory: UL, CUL, CB
    EMC Standard: FCC, CE, C-Tick, BSMI

    Physical Dimensions: 485 (W) x 574 (D) x 132 (H) mm
    Physical Weight: 24 Kgs (without drives)
    Packed Dimensions: 610 (W) x 790 (D) x 450 (H) mm
    Packed Weight: 33 Kgs (without drives)


  ::  GUI PREVIEW
The JanusRAID SA-6643S iSCSI Graphic User Interface requires a java enabled web browser. The GUI enables users to quickly and easily setup and configure their iSCSI subsystem, monitor status, and performance maintenance.

Volume Configuration
    * View health of hard drives
    * Setup Volume Groups (VG)
    * Setup User Data Volume (UDV)
    * Create Cache Volume (CV)
    * Create Snapshots

Enclosure Management
    * SCSI Enclosure Services (SES) configuration
    * Monitor voltage, temperature, and battery backup module
    * S.M.A.R.T. test
    * UPS setup and monitoring (Smart UPS)

System Configuration
    * Setup System name and IP address
    * Change Time, Date, and Timezone
    * SNMP, Mail alerts
    * Event Log viewer

Maintenance
    * Update Firmware
    * View System Information
    * Import and Export Configuration
    * Reset to Factory Defaults

  ::  NOTES
Arena Maxtronic products have a two year product warranty and a thirty day money back guarantee on all products unless otherwise specified.

Firmware Download: 2.2.0

User Manual Download: Hardware | Software

SA-6643S Brochure
:: RELATED PRODUCTS
Arena Maxtronic Battery Backup Unit Kit -#BBUKIT
 

  Send to friend
Your name: *
Your e-mail: *
Recipient's e-mail: *

 Send to friend 
 

  Detailed images
Arena Maxtronic 8-Bay SATA II - U320SCSI 2U Rack Mount RAID, Intel 80331 RISC CPU, Dual Channel Host Connection Option, 512MB RAM, 300WX2 Redundant Hot Swap P/S, Hot Swap HDD Trays - #SA-4340S

 
 
 
 Your cart
Cart is empty

View cart
Checkout

 Authentication
Username

Password

Log in
Register
Recover password

If Javascript is disabled in your browser click here

 News
No news available at the moment

Your name:

Your email:

Subscribe 

 Testimonials
Great Site and Smart Products - I'll be back.
- W. Paterson

Submit a testimonial




www.Trust-Guard.com <http://www.Trust-Guard.com>  - Click To Verify

www.Trust-Guard.com <http://www.Trust-Guard.com>  - Click To Verify

www.Trust-Guard.com <http://www.Trust-Guard.com>  - Click To Verify

www.Trust-Guard.com <http://www.Trust-Guard.com>  - Click To Verify

 

Copyright © 2008 Verge Labs Inc. (Akumen.com)